Search the whole station

Temperture Forcing System/ Jet Impact Testing Machine

ZLT HED Series 10℃~60℃

Chemical medium temperature control unit
  • Temperature Control Accuracy±0.1℃
  • Heating capacity2KW~7.5KW
  • Cooling capacity1KW~6KW

Parameters Detailed

ModelZLT-1HEDZLT-3HEDZLT-6HED
ZLT-1WHEDZLT-3WHEDZLT-6WHED
Temperature range10 ℃~+60℃ Different media, different temperatures
Temperature control accuracy±0.1℃±0.1℃±0.1℃
Cooling capacity20℃1kW3kW6kW
Heating capacity2kw3.5kw7.5kw
Direct cooling methodCompressor
Input, display4.3-inch/7-inch color touch screen\ PLC controller
CommunicationModbus RTU protocol RS485 interface, Ethernet TCP/IP protocol
Heat exchangerSilicon carbide
Interface sizeG3/8G3/8G1/2
Water-cooled @20℃300L/H800L/H1500L/H
G3/8G3/8G1/2
Water-cooled condenserThe condenser of the water-cooled equipment adopts a plate heat exchanger
Air-cooled condenserMicrochannel heat exchangerMicrochannel heat exchangerMicrochannel heat exchanger
Power supplySingle phase 220VThree-phase 380V/220V
Chemical pipe materialPFA
Casing materialCold rolled sheet spraying (REL7035)

Recommended products

  • 半导体 方图 3 1Air Cooling Chiller AET SERIES” />
    Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc. ,
    Air Cooling Chiller AET SERIES

    Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc. ,

  • thermal thuck MDMD -75℃~225℃” />
    -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ Flatness ±50um ±50um ±50um Tablet Size 200mm diameter di…
    MD -75℃~225℃

    -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ Flatness ±50um ±50um ±50um Tablet Size 200mm diameter di…

  • 直冷机2ZLJ -40℃~-15℃” />
    Multiple control requirements can be achieved by merging multiple devices into a larger cabinet Used for small heat exchange area and large heat exchange capacity table {width: 100%;border-collapse: collapse;}th, t…
    ZLJ -40℃~-15℃

    Multiple control requirements can be achieved by merging multiple devices into a larger cabinet Used for small heat exchange area and large heat exchange capacity table {width: 100%;border-collapse: collapse;}th, t…

  • LQGas Cooling Chiller LQ -40°C~-110°C” />
    LQ -110°C~+110°C Gas Cooling Chiller Cooling capacity:0.25kW~25kW Power range:6.5kW~50kW Temperature control accuracy :±0.3℃ Gas flow rate per minute 12m³/h~100m³/h Cooling temperature range:-110°C~+110°C Gas coolin…
    Gas Cooling Chiller LQ -40°C~-110°C

    LQ -110°C~+110°C Gas Cooling Chiller Cooling capacity:0.25kW~25kW Power range:6.5kW~50kW Temperature control accuracy :±0.3℃ Gas flow rate per minute 12m³/h~100m³/h Cooling temperature range:-110°C~+110°C Gas coolin…

loading…

已经是到最后一篇内容了!

Expand more!