COOLING HEATING CIRCULATOR (oil heating type)
  • Heating Power2.5kW~15kW
  • Cooling capacity0.25kW~15kW
  • Power range4.5kW~25kW
  • Medium accuracy±0.5℃
  • RefrigerantR404A/R507C
  • Weight160KG~360KG

Product Description


hrt123 1571278158

HRT Knowledge

The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.

So what are the causes of the blockage of the cooler?

Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.

If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.

Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.

There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.

Parameters Detail

Model HRT-35N HRT-50N HRT-70N HRT-100N HRT-150N
Temp rang -45℃~250℃
Controller Single machine/ASET multifunctional controller, controlling the temperature of the water tank
Temp control Heat-conducting medium outlet temp.control
Temp feedback Heat-conducting medium temperature feedback PT100(measure inlet temperature and outlet temperature)
Temp accuracy ±0.5℃
Heating power KW 3.5kW 5.5kW 7.5kW 10kW 15kW
Cooling
Capacity
kW at
250℃ 3.5kW 5.5kW 7.5kW 10kW 15kW
100℃ 3.5kW 5kW 7kW 10kW 15kW
20℃ 3.5kW 5kW 7kW 10kW 15kW
0℃ 3kW 5kW 7kW 10kW 15kW
 -15℃ 1.5kW 2.8kW 4kW 5.5kW 10kW
 -35℃ 0.45kW 0.9W 1.5kW 2kW 3.75kW
Criculation pump flow Max35L/min Max35L/min Max50L/min Max65L/min Max110L/min
Pressure MAX 1.2BAR 1.2BAR 1.2BAR 1.5BAR 1.5BAR
Compressor Tecumseh/ Emerson copeland
Evaporator Plate heat exchanger
Input、display Display setting temperature and outlet and inlet temperature, 7-inch color touch screen
Date record U disk data export, Excel form, error record
Temp record Record setting temperature, outlet and inlet temperature
Safety Protection Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection
device and other safety protection
Closed Circulation
System
The whole system is full closed circulation, there is no oil mist at high temp. and no water vapor at low temp.,
pressure do not rise up when system is running. The system will supplement oil automatically at low temperature
Refrigerant R-404A/R507C
Connection size ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Dimension cm 45*70*160 55*70*175 55*70*175 65*85*185 70*85*185
Weight 185kg 245kg 245kg 320kg 360kg
Power max
AC 380V 50HZ
6.2kW 9kW 14kW 16kW 23kW
Case material Cold rolled steel powder coating (standard color 7035)
Optional ODBUS RTU Protocl, RS 232 interface
Optional Power 220V 60HZ three-phase, 440V~460V 60HZ three phase

recommend products

  • sr 6Single Fluid Heat Transfer System SR” />
    TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of…
    Single Fluid Heat Transfer System SR

    TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of…

  • zlf 5Reactor Temperature System ZLF” />
    Special temperature control system for reaction kettle -120~250℃ 士1°C TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infr…
    Reactor Temperature System ZLF

    Special temperature control system for reaction kettle -120~250℃ 士1°C TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infr…

loading…

已经是到最后一篇内容了!

Expand more!