AET -75℃~250℃
Air Cooling Chiller For chuck/chamber/Heat plate- Temperature Control Accuracy±0.5℃
- Air treatment22m³/h~95m³/h
- Cooling Typewater cooling/air cooling
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
Parameters Detailed
Model | AET-4025 | AET-4050 | AET-4095W | AET-7025 | AET-7050W | AET-7095W |
AET-4025C | AET-4050C | AET-4095WC | AET-7025C | AET-7050WC | AET-7095WC | |
Temperature range | -40℃~250℃ | -75℃~250℃ | ||||
Temperature control accuracy | Gas outlet temperature control ±0.1°C, long-distance process temperature control accuracy ±0.5°C. You can choose to control the outlet gas temperature and process target temperature. | |||||
Upgrade temperature rate | The temperature rise and fall rate of the gas temperature at the equipment outlet is greater than 30°C/min, and gradient temperature rise and fall can be performed. | |||||
Air requirements | Air filter <5um Air oil content <0.1um Air temperature and humidity: 5°C-32℃ 0-50%RH Pressure 4bar~8bar. | |||||
Air treatment | 22m³/h | 50m³/h | 95m³/h | 22m³/h | 50m³/h | 95m³/h |
Throttling method | The refrigeration system uses electronic expansion valve throttling to accurately control the cooling capacity. | |||||
Controller | PLC programmable controller, standard support Modbus RTU protocol, RS485 interface, other communication protocols can be selected. | |||||
Display record | 7-inch color touch screen, can display gas temperature, pressure, flow, refrigeration system pressure and temperature. | |||||
Process temperature control | Self-created model-free self-building tree algorithm combined with general anti-lag cascade algorithm to control process temperature. | |||||
Dimensions cm | 43*46*112 | 52*57*132 | 60*63*160 | 54*69*112 | 65*85*132 | 75*95*160 |
Remarks | Suffix W represents water cooling and suffix C represents gas recycling. |
Recommended products
MD -75℃~225℃” />
-75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ Flatness ±50um ±50um ±50um Tablet Size 200mm diameter di… MD -75℃~225℃-75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature uniformity ±1℃ ±1℃ ±1℃ Flatness ±50um ±50um ±50um Tablet Size 200mm diameter di…
ZLJ -40℃~-15℃” />
Multiple control requirements can be achieved by merging multiple devices into a larger cabinet Used for small heat exchange area and large heat exchange capacity table {width: 100%;border-collapse: collapse;}th, t… ZLJ -40℃~-15℃Multiple control requirements can be achieved by merging multiple devices into a larger cabinet Used for small heat exchange area and large heat exchange capacity table {width: 100%;border-collapse: collapse;}th, t…
Gas Cooling Chiller LQ -40°C~-110°C” />
LQ -110°C~+110°C Gas Cooling Chiller Cooling capacity:0.25kW~25kW Power range:6.5kW~50kW Temperature control accuracy :±0.3℃ Gas flow rate per minute 12m³/h~100m³/h Cooling temperature range:-110°C~+110°C Gas coolin… Gas Cooling Chiller LQ -40°C~-110°CLQ -110°C~+110°C Gas Cooling Chiller Cooling capacity:0.25kW~25kW Power range:6.5kW~50kW Temperature control accuracy :±0.3℃ Gas flow rate per minute 12m³/h~100m³/h Cooling temperature range:-110°C~+110°C Gas coolin…
Temperture Forcing System/ Jet Impact Testing Machine” />
Temperature forcing system is Thermal Stream Equipment AES series Temperture Forcing System/ Jet Impact Testing MachineTemperature forcing system is Thermal Stream Equipment AES series
loading…