Search the whole station

SUNDI -10℃~150℃

Two-box test chamber

-70℃~100℃
  • Cooling rate(No load) (+20 ℃~-40 ℃) 1 ℃/min
  • Temperature uniformity≤± 1 ℃ (unloaded)
  • Temperature accuracy≤±0.5℃
  • Temperature accuracy≤±0.1℃

Configuration Details

Model GD-300-2-B1-LX
Inner box size
(W*H*D)cm
Upper cavity (cm) 85*60*60
Lower cavity (cm) 85*60*60
Temperature range -40℃~100℃ (-70℃ can be customized)
Heating rate (No load) (+20~150℃) 1℃/min (5~25℃ can be customized)
Cooling rate (No load) (+20~-40℃) 1℃/min (5~25℃ can be customized)
Temperature uniformity ≤±1℃ (no load)
Temperature fluctuation ≤±0.5℃
Temperature accuracy ≤±0.1℃
Window size (cm) 300*450
Refrigerant R404A
Test hole φ100mm×1
Heater Electric heating
Air-cooled condenser Fin heat exchanger
Water-cooled condenser Plate/jacket/shell and tube heat exchanger
Air circulation Extended shaft motor, stainless steel centrifugal fan blades
Cooling method Single stage refrigeration
Compressor Brand inverter compressor
Control method Segmented fuzzy PID algorithm control
Communication protocol interface TCP/RS485 (CAN can be customized)
Operation panel 7-inch color touch screen, temperature curve display\EXCEL data export
Sensor PT100A grade platinum resistor
Protective devices Heater dual temperature protection, refrigeration system protection and electrical overcurrent and overload protection, etc.
Outer box size
(W*H*D)cm
111*195*172
Power supply 380V 50HZ
Insulation material Glass fiber wool & polyurethane
Inner box material SUS304 stainless steel
Outer box material Cold rolled steel plate + plastic spraying
Execution meets standards GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068-3-5

You may also be interested in these products

  • kry zhutuSUNDI Z Frequency conversion series” />
    HIGHLY TEMPERATURE CONTROL SYSTEMS SUNDI Z Frequency Conversion Series Cooling capacity:0.4kW~60kW Heating Power:3.5kW~60kW Temperature control accuracy :±0.1℃ Refrigerant:R404A/R507C/R508B Weight:115KG~300KG -80℃~…
    SUNDI Z Frequency conversion series

    HIGHLY TEMPERATURE CONTROL SYSTEMS SUNDI Z Frequency Conversion Series Cooling capacity:0.4kW~60kW Heating Power:3.5kW~60kW Temperature control accuracy :±0.1℃ Refrigerant:R404A/R507C/R508B Weight:115KG~300KG -80℃~…

  • 12 11SUNDI -10℃~150℃” />
    Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[becau…
    SUNDI -10℃~150℃

    Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[becau…

  • 45 7SUNDI -45℃~300℃” />
    ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heati…
    SUNDI -45℃~300℃

    ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heati…

  • 1 68SUNDI -80℃~250℃” />
    ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heating …
    SUNDI -80℃~250℃

    ● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heating …

loading…

已经是到最后一篇内容了!

Expand more!