INDOOR WATER CHILLER
LTZ M variable frequency series- Cooling capacity @20℃3kW~87kW
- RefrigerantR407C
- Place of OriginChina
It is suitable for the target temperature control object that already has a cold storage tank and a circulating pump. The medium is transported to the LTZ M series refrigeration unit through the circulating pump, which is a closed-loop refrigeration system.
Industry temperature control solutions
LTZ variable frequency chiller
The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user’s cooling and heating load requirements through the built-in frequency conversion device. The variable frequency unit adopts advanced frequency conversion technology to accurately control the compression and fan operating speed.
DETAIL ADVANTAGE,STRIVING FOR EXCELLENCE

Parameter
Model | LTZ-1 M | LTZ-3M | LTZ-6M | LTZ-15M | LTZ-25WM |
LTZ-3WM | LTZ-6WM | LTZ-15WM | |||
Temperature range | 5 ℃~30℃ (Use ethylene glycol water solution below 10℃) | ||||
Temperature control accuracy | ±0.5℃ | ||||
Temperature feedback | Pt100 | ||||
Cooling capacity at 20℃ | 3kW | 10.5kW | 21kW | 52kW | 87kW |
Compressor | Mitsubishi, Hitachi | Variable frequency compressor | |||
Throttling method | Thermal expansion valve | Electronic expansion valve | |||
DI heat exchanger | Plate heat exchanger | ||||
Input, display | 4.3-inch touch screen | 7-inch color touch screen\ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface | ||||
Safety protection | It has self-diagnosis function; refrigerator overload protection; high and low voltage protection, overload relay, thermal protection device, exhaust and suction temperature protection, sensor fault protection and other safety protection functions.。 | ||||
Refrigerant | R407C | ||||
Interface size | G1/2 | G3/4 | G3/4 | ||
Water-cooled type @20℃ | 600L/H | 1800L/H | 3600L/H | 9000L/H | 15000L/H |
G3/4 | G1 | DN32 PN10 | DN40 PN10 | ||
Water-cooled condenser | The condenser of the water-cooled equipment uses a plate heat exchanger and requires a closed cooling tower for water supply | ||||
Air-cooled condenser | Microchannel heat exchanger | ||||
Power supply | 380V 50HZ can choose three-phase 220V 460V | ||||
Contact pipe material | SUS304 | ||||
Casing material | Cold rolled plate sprayed (REL7035) |
WIND COLD WATER COLD ON DEMAND SELECTION

The circulating fluid from the pump is cooled by the customer’s equipment and then returns to the thermostat. The circulating fluid passes through the refrigeration circuit, reaches the set temperature, and is then output to the customer’s device side through the thermostat.
CASCADECOMMUNICATION REMOTE OPERATION

According to the serial communication remote control signal input and output, one of the contact inputs can be remotely operated using serial communication for remote operation, and the other is used to monitor the flow through the flow switch and read the alarm output.
Alarm, operating status (start, stop, etc.)
Signal output
The alarm and status inside the temperature controller can be divided into 3 output signals according to their content.
recommend products
LT -60℃~-20℃” />
Circulating refrigeration of ethylene glycol mixed with water mixture Temperature ranges from -80℃~+30℃;Adopt using secondary sub cooling technology, rapid cooling and low temp Limit;Adopt famous brand semi-cl… LT -60℃~-20℃Circulating refrigeration of ethylene glycol mixed with water mixture Temperature ranges from -80℃~+30℃;Adopt using secondary sub cooling technology, rapid cooling and low temp Limit;Adopt famous brand semi-cl…
LT -80℃~-20℃” />
It can guarantee 24-hour continuous operation Circulating refrigeration of ethylene glycol mixed with water mixture 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Cir… LT -80℃~-20℃It can guarantee 24-hour continuous operation Circulating refrigeration of ethylene glycol mixed with water mixture 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Cir…
LT -45℃~30℃” />
LOW TEMPERATURE COOLING CIRCULATOR For fast liquid cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong t… LT -45℃~30℃LOW TEMPERATURE COOLING CIRCULATOR For fast liquid cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong t…
LT -25℃~30℃” />
Rapid refrigeration using imported brand semi-enclosed piston compressor, semi-enclosed piston two-stage compressor, semi-enclosed screw compressor 1. Can use ethylene glycol mixed … LT -25℃~30℃Rapid refrigeration using imported brand semi-enclosed piston compressor, semi-enclosed piston two-stage compressor, semi-enclosed screw compressor 1. Can use ethylene glycol mixed …
loading…
已经是到最后一篇内容了!