Cooling Heating Circulator
HR-25℃~200℃- Heating Power2.5kW~15kW
- Cooling capacity1kW~15kW
- Power range4kW~21kW
- Medium accuracy±0.5℃
- RefrigerantR404A/R507C
- Weight150KG~320KG
Parameters Detail
Model | HR-25N | HR-35N | HR-50N | HR-70N | HR-100N | HR-150N | |
---|---|---|---|---|---|---|---|
Temperature Range | -25℃~200℃ | ||||||
Controller | PID adaptive controller | ||||||
Temperature Control | Heat-conducting medium outlet temperature control | ||||||
Temperature Feedback | PT100 (measures inlet and outlet temperature) | ||||||
Temp. Accuracy | ±0.5℃ | ||||||
Heating Power | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
Cooling Capacity | 200℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW |
100℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
20℃ | 2.5kW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
-5℃ | 2kW | 3kW | 4.5kW | 6.6kW | 8kW | 12kW | |
-20℃ | 1kW | 1.8kW | 2.8kW | 3.8kW | 4.6kW | 7kW | |
Circulation Pump Flow | Max 20L/min | Max 35L/min | Max 35L/min | Max 50L/min | Max 60L/min | Max 110L/min | |
Circulation Pump Pressure | 1.2BAR | 1.2BAR | 1.2BAR | 1.2BAR | 1.5BAR | 1.5BAR | |
Tank Volume | Volume | 8L | 13L | 15L | 18L | 22L | 30L |
Details | Equipped with expansion tank connection (ZG1/2) | ||||||
Compressor | Mitsubishi | Copeland | Copeland | Copeland | Copeland | Copeland | |
Evaporator | Plate heat exchanger | ||||||
Operation Panel | Displays settings and temperature, 7-inch touch screen | ||||||
Data Record | USB export in Excel format with error logs | ||||||
Safety Protection | Overload protection, high-pressure switch, self-diagnosis, etc. | ||||||
Closed Circulation System | Fully closed, no oil mist or water vapor, automatic oil replenishment | ||||||
Refrigerant | R-404A/R507C | ||||||
Connection Size | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Dimensions | Air-cooled | 40×70×130 | 45×70×160 | 45×70×160 | 55×70×175 | 65×85×185 | 70×85×185 |
Weight | 150kg | 165kg | 235kg | 265kg | 290kg | 320kg | |
Power | Voltage | AC 220V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ | AC 380V 50HZ |
Max Power | 4kW | 5.6kW | 8kW | 11kW | 15.5kW | 22kW | |
Case Material | Cold-rolled steel | ||||||
Optional | MODBUS RTU Protocol, RS 232 interface | ||||||
Optional Power | 220V 60HZ three-phase, 440V–480V 60HZ three-phase |
Product Description
HRT Knowledge
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.
So what are the causes of the blockage of the cooler?
Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.
If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.
Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.
There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.
recommend products
SUNDI Z Frequency conversion series” />
HIGHLY TEMPERATURE CONTROL SYSTEMS SUNDI Z Frequency Conversion Series Cooling capacity:0.4kW~60kW Heating Power:3.5kW~60kW Temperature control accuracy :±0.1℃ Refrigerant:R404A/R507C/R508B Weight:115KG~300KG -80℃~… SUNDI Z Frequency conversion seriesHIGHLY TEMPERATURE CONTROL SYSTEMS SUNDI Z Frequency Conversion Series Cooling capacity:0.4kW~60kW Heating Power:3.5kW~60kW Temperature control accuracy :±0.1℃ Refrigerant:R404A/R507C/R508B Weight:115KG~300KG -80℃~…
SUNDI -10℃~150℃” />
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[becau… SUNDI -10℃~150℃Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[becau…
SUNDI -45℃~300℃” />
● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heati… SUNDI -45℃~300℃● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heati…
SUNDI -80℃~250℃” />
● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heating … SUNDI -80℃~250℃● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heating …
loading…
已经是到最后一篇内容了!