HRT -45℃~250℃
COOLING HEATING CIRCULATOR (oil heating type)- Heating Power2.5kW~15kW
- Cooling capacity0.25kW~15kW
- Power range4.5kW~25kW
- Medium accuracy±0.5℃
- RefrigerantR404A/R507C
- Weight160KG~360KG
Product Description
HRT Knowledge
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.
So what are the causes of the blockage of the cooler?
Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.
If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.
Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.
There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.
Parameters Detail
Model | HRT-35N | HRT-50N | HRT-70N | HRT-100N | HRT-150N | |
Temp rang | -45℃~250℃ | |||||
Controller | Single machine/ASET multifunctional controller, controlling the temperature of the water tank | |||||
Temp control | Heat-conducting medium outlet temp.control | |||||
Temp feedback | Heat-conducting medium temperature feedback PT100(measure inlet temperature and outlet temperature) | |||||
Temp accuracy | ±0.5℃ | |||||
Heating power KW | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | |
Cooling Capacity kW at |
250℃ | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW |
100℃ | 3.5kW | 5kW | 7kW | 10kW | 15kW | |
20℃ | 3.5kW | 5kW | 7kW | 10kW | 15kW | |
0℃ | 3kW | 5kW | 7kW | 10kW | 15kW | |
-15℃ | 1.5kW | 2.8kW | 4kW | 5.5kW | 10kW | |
-35℃ | 0.45kW | 0.9W | 1.5kW | 2kW | 3.75kW | |
Criculation pump flow | Max35L/min | Max35L/min | Max50L/min | Max65L/min | Max110L/min | |
Pressure MAX | 1.2BAR | 1.2BAR | 1.2BAR | 1.5BAR | 1.5BAR | |
Compressor | Tecumseh/ Emerson copeland | |||||
Evaporator | Plate heat exchanger | |||||
Input、display | Display setting temperature and outlet and inlet temperature, 7-inch color touch screen | |||||
Date record | U disk data export, Excel form, error record | |||||
Temp record | Record setting temperature, outlet and inlet temperature | |||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection device and other safety protection |
|||||
Closed Circulation System |
The whole system is full closed circulation, there is no oil mist at high temp. and no water vapor at low temp., pressure do not rise up when system is running. The system will supplement oil automatically at low temperature |
|||||
Refrigerant | R-404A/R507C | |||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Dimension cm | 45*70*160 | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | |
Weight | 185kg | 245kg | 245kg | 320kg | 360kg | |
Power max AC 380V 50HZ |
6.2kW | 9kW | 14kW | 16kW | 23kW | |
Case material | Cold rolled steel powder coating (standard color 7035) | |||||
Optional | ODBUS RTU Protocl, RS 232 interface | |||||
Optional Power | 220V 60HZ three-phase, 440V~460V 60HZ three phase |
recommend products
Single Fluid Heat Transfer System SR” />
TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of… Single Fluid Heat Transfer System SRTCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of…
Reactor Temperature System ZLF” />
Special temperature control system for reaction kettle -120~250℃ 士1°C TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infr… Reactor Temperature System ZLFSpecial temperature control system for reaction kettle -120~250℃ 士1°C TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infr…