| Model | FL-800 | ||||||||
| Temperature range | -18 ~ +30 °C | ||||||||
| Cooling capacity | 0.35 – 0.9 kW | ||||||||
| Temperature stability | ±0.5 ℃ | ||||||||
| Pump flow pressure | 25 – 250 L/min | ||||||||
| Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized | |||||||||


Search the whole station
for pharmeucital/laboratory/semiconductor/automotive…
LNEYA a leading global manufacturer with 20+ year experience in research, development & production of water chillers – from mini chillers to large screw chillers with tons of cooling capacity, to keep cool for various industrial processing. We have designed OEM chillers for aerospace, automotive, energy, chemical, industrial, medical, and semiconductor application, all delivered with capabilities specific to the demanding needs of our customers.

| Model | LT-25℃~30℃ | LT-45℃~30℃ | LT-60℃~-30℃ | LT-80℃~-40℃ | |
| Cooling capacity -15℃ |
1.5kw~5kw@-15℃ | 0.7kw~2.5kw@-35℃ | 1.3kw~4.8kw@-40℃ | 0.7kw~2.5kw@-60℃ | |
| Circulation Pump Flow MAX |
30L/min 1.6bar | ||||
| Refrigerant | R-404A / R507C | R-404A / R507C | R-404A/R23 | R-404A/R23 | |
| Temp control accuracy | ±0.5℃ | ||||
| Temperature feedback | Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||
| Compressor | Highly, Mitsubishi, Panasonic and other compressors | ||||
| Evaporator | Plate Heat Exchanger | ||||
| Operation panel | 4.3-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
| Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions |
||||
| Power | AC220V / AC380V/ AC460V | ||||
| Shell material | Cold rolled sheet (REL7035) | ||||
| Communication protocol | Communication protocol MODBUS RTU protocol RS485 interface | ||||

| Model | LTZ-25℃~30℃ | LTZ-45℃~30℃ | LTZ -60℃~-30℃ | LTZ -80℃~-40℃ | |
| Cooling capacity -15℃ |
1.5kw~5kw@-15℃ | 0.7kw~2.5kw@-35℃ | 1.3kw~4.8kw@-40℃ | 0.7kw~2.5kw@-60℃ | |
| Circulation Pump Flow MAX |
30L/min 1.6bar | ||||
| Refrigerant | R-404A / R507C | R-404A / R507C | R-404A/R23 | R-404A/R23 | |
| Temp control accuracy | ±0.5℃ | ||||
| Temperature feedback | Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||
| Compressor | Highly, Mitsubishi, Panasonic and other compressors | ||||
| Evaporator | Plate Heat Exchanger | ||||
| Operation panel | 4.3-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
| Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions |
||||
| Power | AC220V / AC380V/ AC460V | ||||
| Shell material | Cold rolled sheet (REL7035) | ||||
| Communication protocol | Communication protocol MODBUS RTU protocol RS485 interface | ||||

| Model | FL-800 | ||||||||
| Temperature range | -18 ~ +30 °C | ||||||||
| Cooling capacity | 0.35 – 0.9 kW | ||||||||
| Temperature stability | ±0.5 ℃ | ||||||||
| Pump flow pressure | 25 – 250 L/min | ||||||||
| Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized | |||||||||

| Model | FLT series | FLT-2 series | FLT-4 series | FLT-8 series | FLT-10 series |
| Temperature range | +5 ~ +40 °C | -25 ~ +40 °C | -45 ~ +40 °C | -80 ~ +80 °C | -100 ~ +80 °C |
| Cooling capacity | 6 – 40 kW | 2 – 15 kW | 1 – 8 kW | 0.6 – 3 kW | 1.5 – 3 kW |
| Temperature stability | ±0.1 ℃ | ||||
| Pump flow pressure | 10 – 75 L/min | 7 – 45 L/min | |||
| Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized | |||||

| LG SERIES | 5℃~30℃ | -25℃~5℃ | -45℃~-10℃ | -60℃~-10℃ | -80℃~-30℃ | -110°C~ -50°C |
| Cooling Capacity | 236KW~936KW | 80KW~318JW | 50KW~180KW | 66KW~238KW | 36KW~131KW | 9KW~32KW |
| Chilled water volumeT/H | 40KW~160KW | 24KW~92KW | 23KW~83KW | 34KW~123KW | 22KW~82KW | 3KW~10KW |
| Cooling water volumeT/H | 51KW~201KW | 26KW~99KW | 16KW~60KW | 26KW~94KW | 18KW~65KW | 8KW~97KW |
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
|||||
| Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | |||||
| Form | Plate, dry, overflow or falling film heat exchanger | |||||
We provide corresponding chiller solutions for almost all industries, supporting heating and cooling functions
We provide complete chillers design and manufacturing. From standard models to complete customized products.We specialized in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
Our online customer service is in the lower right corner. Please feel free to reply to your message during working hours (or leave us a message, we will solve your chiller needs as soon as possible)


| Aerospace | Anodizing & Plating | Automotive | Battery |
| Biotechnology | Brewery | Cannabis Extraction & Distillation | Casting Industry |
| Chemical | Commercial Buildings and Homes | Converting Industry | Cosmetics Workshops |
| Dairy Milk Processing | Data Center | Die Casting | Electric Car Battery |
| Energy Storage | Food & Beverage | Hazardous Processing | Heat Treating |
| Hospitals | Hydraulic Press | Industrial Manufacturing | Injection Molding |
| Integrated circuits test | Laboratory | Laser Cutting | Marine Solutions |
| Medical | Metal Finishing | Mining | Misting Equipment |
| Optical Coating | Paint Production Workshops | Pharmaceutical | Plastics Processing |
| Oil and Gas | Power Generation | Printing | Reactors |
| Renewable Natural Gas | Rotary Evaporator | Semiconductor Manufacturing | Textile and Yarn Industry |
| Thermal Spray | Thermal Vacuum Test | Waste Water Treatment | Welding Machines |
From the moment you have a need for temperature control to the moment you receive our chiller, we are always professional.
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.

Can’t find a suitable chiller? Or don’t know how to choose a chiller? Contact us now to get chiller details and prices