Temperature range -110℃~30℃
Temperature control accuracy: ±0.1℃
| Model | LG1-75W | LG1-100W | LG1-140W | LG1-180W | LG1-230W | LG1-280W | |
| Temperature range | 5℃~30℃ | ||||||
| Cooling capacity 7℃ |
kW | 236 | 328 | 468 | 608 | 762 | 936 |
| Kcal/hr*10³ | 202.9 | 282.1 | 402.5 | 522.9 | 655.3 | 805.0 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (7℃) | 64 | 84 | 120 | 155 | 191 | 236 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 40 | 56 | 80 | 104 | 131 | 160 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN80 | DN100 | DN125 | DN150 | |||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 51 | 71 | 101 | 131 | 163 | 201 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN80 | DN100 | DN150 | DN200 | |||
| Model | LG2-75W | LG2-100W | LG2-140W | LG2-180W | LG2-230W | LG2-280W | |
| Temperature range | -25℃~5℃ | ||||||
| Cooling capacity -20℃ |
kW | 80 | 111 | 158 | 206 | 259 | 318 |
| Kcal/hr*10³ | 68.8 | 95.5 | 135.9 | 177.2 | 222.7 | 273.5 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (-20℃) | 56 | 74 | 105 | 136 | 166 | 205 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 24 | 32 | 46 | 59 | 75 | 92 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN65 | DN80 | DN100 | DN125 | |||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 26 | 35 | 50 | 65 | 80 | 99 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN80 | DN100 | DN125 | DN150 | |||
| Model | LG4-75W | LG4-100W | LG4-140W | LG4-180W | LG4-230W | LG4-280W | |
| Temperature range | -45℃~-10℃ | ||||||
| Cooling capacity -40℃ |
kW | 50 | 70 | 95 | 120 | 155 | 180 |
| Kcal/hr*10³ | 43 | 60.2 | 81.7 | 103.2 | 133.3 | 154.8 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (-40℃) | 35 | 48 | 65 | 82 | 106 | 113 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 23 | 32 | 44 | 56 | 72 | 83 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN65 | DN80 | DN100 | DN125 | |||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 16 | 20 | 30 | 36 | 46 | 60 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN65 | DN80 | DN100 | DN125 | |||
| Model | LG6-75 | LG6-100W | LG6-140W | LG6-180W | LG6-230W | LG6-280W | |
| Temperature range | -60℃~-10℃ | ||||||
| Cooling capacity -55℃ |
kW | 66 | 87 | 121 | 158 | 202 | 238 |
| Kcal/hr*10³ | 56.7 | 74.8 | 104.0 | 135.8 | 173.7 | 204.6 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (-55℃) | 103 | 135 | 192 | 249 | 310 | 375 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 34 | 45 | 63 | 82 | 105 | 123 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN80 | DN100 | DN125 | ||||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 26 | 34 | 48 | 62 | 79 | 94 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN80 | DN100 | DN125 | DN150 | |||
| Model | LG8-75W | LG8-100W | LG8-140W | LG8-180W | LG8-230W | LG8-280W | |
| Temperature range | -80℃~-30℃ | ||||||
| Cooling capacity -75℃ |
kW | 36 | 48 | 67 | 88 | 112 | 131 |
| Kcal/hr*10³ | 30.9 | 41.3 | 54.2 | 72.2 | 96.3 | 112..3 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (-75℃) | 83 | 110 | 156 | 203 | 254 | 308 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 22 | 30 | 36 | 55 | 70 | 82 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN65 | DN80 | DN100 | ||||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 18 | 23 | 31 | 43 | 54 | 65 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN65 | DN80 | DN100 | DN125 | |||
| Model | LG11-75W | LG11-100W | LG11-140W | LG11-180W | LG11-230W | LG11-280W | |
| Temperature range | -110°C~ -50°C | ||||||
| Cooling capacity -105℃ |
kW | 9 | 12 | 16 | 22 | 28 | 32 |
| Kcal/hr*10³ | 7.7 | 10.3 | 13.8 | 18.9 | 24.1 | 27.5 | |
| Power | 3N/400V/50HZ | ||||||
| Cooling input power at (-105℃) | 56 | 75 | 105 | 135 | 172 | 210 | |
| Compressor | Form | semi-closed double screw compressor | |||||
| Heat control range | 25%~100% | ||||||
| Chilled water | Form | Plate, dry, overflow or falling film heat exchanger | |||||
| Chilled water volumeT/H | 3 | 4 | 5 | 7 | 8 | 10 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN40 | DN50 | DN65 | ||||
| Cooling water | Form | Horizontal tubular heat exchanger | |||||
| Cooling water volumeT/H | 8 | 10 | 14 | 19 | 24 | 27 | |
| Water pressure drop | 40~80 | ||||||
| Connection size | DN50 | DN65 | DN80 | ||||




Where project can we use in?
We work with businesses just like yours to keep operations running. Small workshops and large production plants alike rely on our water chiller systems to keep equipment and processes on track! (A-Z)
| Aerospace | Anodizing & Plating | Automotive | Battery |
| Biotechnology | Brewery | Cannabis Extraction & Distillation | Casting Industry |
| Chemical | Commercial Buildings and Homes | Converting Industry | Cosmetics Workshops |
| Dairy Milk Processing | Data Center | Die Casting | Electric Car Battery |
| Energy Storage | Food & Beverage | Hazardous Processing | Heat Treating |
| Glass reactors | Hydraulic Press | Industrial Manufacturing | Injection Molding |
| Integrated circuits test | Laboratory | Laser Cutting | Lathes cooling |
| Semiconductor FAB | Metal Finishing | Mining | Misting Equipment |
| Optical Coating | Paint Production Workshops | Pharmaceutical | Plastics Processing |
| Oil and Gas | Power Generation | Printing | Reactors |
| Renewable Natural Gas | Rotary Evaporator | Semiconductor Manufacturing | Textile and Yarn Industry |
| Thermal Spray | Thermal Vacuum Test | Waste Water Treatment | Welding Machines |
Visit Our Factory
From the moment you have a need for temperature control to the moment you receive our chiller, we are always professional.
Our online customer service is in the lower right corner. Please feel free to reply to your message during working hours (or leave us a message, we will solve your chiller needs as soon as possible)
Request a quote
It can guarantee 24-hour continuous operation Circulating refrigeration of ethylene glycol mixed with water mixture 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Cir…
LOW TEMPERATURE COOLING CIRCULATOR For fast liquid cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong t…
Circulating refrigeration of ethylene glycol mixed with water mixture Temperature ranges from -80℃~+30℃;Adopt using secondary sub cooling technology, rapid cooling and low temp Limit;Adopt famous brand semi-cl…
Rapid refrigeration using imported brand semi-enclosed piston compressor, semi-enclosed piston two-stage compressor, semi-enclosed screw compressor 1. Can use ethylene glycol mixed …
loading…