Temperture Forcing System/ Jet Impact Testing Machine

ZLT HED Series 10℃~60℃

Chemical medium temperature control unit
  • Temperature Control Accuracy±0.1℃
  • Heating capacity2KW~7.5KW
  • Cooling capacity1KW~6KW

Parameters Detailed

ModelZLT-1HEDZLT-3HEDZLT-6HED
ZLT-1WHEDZLT-3WHEDZLT-6WHED
Temperature range10 ℃~+60℃ Different media, different temperatures
Temperature control accuracy±0.1℃±0.1℃±0.1℃
Cooling capacity20℃1kW3kW6kW
Heating capacity2kw3.5kw7.5kw
Direct cooling methodCompressor
Input, display4.3-inch/7-inch color touch screen\ PLC controller
CommunicationModbus RTU protocol RS485 interface, Ethernet TCP/IP protocol
Heat exchangerSilicon carbide
Interface sizeG3/8G3/8G1/2
Water-cooled @20℃300L/H800L/H1500L/H
G3/8G3/8G1/2
Water-cooled condenserThe condenser of the water-cooled equipment adopts a plate heat exchanger
Air-cooled condenserMicrochannel heat exchangerMicrochannel heat exchangerMicrochannel heat exchanger
Power supplySingle phase 220VThree-phase 380V/220V
Chemical pipe materialPFA
Casing materialCold rolled sheet spraying (REL7035)

Recommended products