Cooling Heating Circulator

HR-25℃~200℃
  • Heating Power2.5kW~15kW
  • Cooling capacity1kW~15kW
  • Power range4kW~21kW
  • Medium accuracy±0.5℃
  • RefrigerantR404A/R507C
  • Weight150KG~320KG

Parameters Detail

Model HR-25N HR-35N HR-50N HR-70N HR-100N HR-150N
Temperature Range -25℃~200℃
Controller PID adaptive controller
Temperature Control Heat-conducting medium outlet temperature control
Temperature Feedback PT100 (measures inlet and outlet temperature)
Temp. Accuracy ±0.5℃
Heating Power 2.5kW 3.5kW 5.5kW 7kW 10kW 15kW
Cooling Capacity 200℃ 2.5kW 3.5kW 5.5kW 7kW 10kW 15kW
100℃ 2.5kW 3.5kW 5.5kW 7kW 10kW 15kW
20℃ 2.5kW 3.5kW 5.5kW 7kW 10kW 15kW
-5℃ 2kW 3kW 4.5kW 6.6kW 8kW 12kW
-20℃ 1kW 1.8kW 2.8kW 3.8kW 4.6kW 7kW
Circulation Pump Flow Max 20L/min Max 35L/min Max 35L/min Max 50L/min Max 60L/min Max 110L/min
Circulation Pump Pressure 1.2BAR 1.2BAR 1.2BAR 1.2BAR 1.5BAR 1.5BAR
Tank Volume Volume 8L 13L 15L 18L 22L 30L
Details Equipped with expansion tank connection (ZG1/2)
Compressor Mitsubishi Copeland Copeland Copeland Copeland Copeland
Evaporator Plate heat exchanger
Operation Panel Displays settings and temperature, 7-inch touch screen
Data Record USB export in Excel format with error logs
Safety Protection Overload protection, high-pressure switch, self-diagnosis, etc.
Closed Circulation System Fully closed, no oil mist or water vapor, automatic oil replenishment
Refrigerant R-404A/R507C
Connection Size ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Dimensions Air-cooled 40×70×130 45×70×160 45×70×160 55×70×175 65×85×185 70×85×185
Weight 150kg 165kg 235kg 265kg 290kg 320kg
Power Voltage AC 220V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ
Max Power 4kW 5.6kW 8kW 11kW 15.5kW 22kW
Case Material Cold-rolled steel
Optional MODBUS RTU Protocol, RS 232 interface
Optional Power 220V 60HZ three-phase, 440V–480V 60HZ three-phase

Product Description


hrt123 1571278158

HRT Knowledge

The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.

So what are the causes of the blockage of the cooler?

Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.

If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.

Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.

There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.